<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>TEMPERATURE CALIBRATOR &#8211; V Tech Group</title>
	<atom:link href="https://v-techgroup.com/product-tag/temperature-calibrator/feed/" rel="self" type="application/rss+xml" />
	<link>https://v-techgroup.com</link>
	<description></description>
	<lastBuildDate>Tue, 04 Mar 2025 09:17:08 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://v-techgroup.com/wp-content/uploads/2026/01/cropped-fav-vtech-32x32.jpg</url>
	<title>TEMPERATURE CALIBRATOR &#8211; V Tech Group</title>
	<link>https://v-techgroup.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>MARSEN TEMPERATURE CALIBRATOR</title>
		<link>https://v-techgroup.com/product/marsen-temperature-calibrator/</link>
		
		<dc:creator><![CDATA[V Tech Admin]]></dc:creator>
		<pubDate>Mon, 30 Dec 2024 08:45:10 +0000</pubDate>
				<guid isPermaLink="false">http://v-techgroup.com/?post_type=product&#038;p=3003</guid>

					<description><![CDATA[GENERAL INFORMATION • When it comes to ensuring the reliable functioning of machines and industrial plants, exact temperature measurement or monitoring is necessary. Incorrectly displayed temperature readings increase the risk of failure. • Temperature is one of the most important indicators for product quality. • Exact measurement ensures consistency in the quality of products FEATURE ]]></description>
										<content:encoded><![CDATA[<p><strong><a href="https://v-techgroup.com/wp-content/uploads/2022/07/Untitled-2-1.png"><img fetchpriority="high" decoding="async" class="alignnone wp-image-2704 size-full" src="https://v-techgroup.com/wp-content/uploads/2022/07/Untitled-2-1.png" alt="" width="800" height="490" /></a></strong></p>
<p>GENERAL INFORMATION<br />
• When it comes to ensuring the reliable functioning of machines and industrial plants, exact temperature measurement or monitoring is necessary.<br />
Incorrectly displayed temperature readings increase the risk of failure.<br />
• Temperature is one of the most important indicators for product quality.<br />
• Exact measurement ensures consistency in the quality of products</p>
<p><strong>FEATURE &amp; ADVANTAGE</strong><br />
• Optimized burning efficiency &amp; fuel consumption<br />
• Reduces engines maintenance costs, overhaul costs and pollution</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Temperature Dry Block Calibrator ED-800 (50˚C to 800 ˚C)</title>
		<link>https://v-techgroup.com/product/temperature-dry-block-calibrator-ed-800-50%cb%9ac-to-800-%cb%9ac/</link>
		
		<dc:creator><![CDATA[V Tech Admin]]></dc:creator>
		<pubDate>Mon, 30 Dec 2024 08:44:49 +0000</pubDate>
				<guid isPermaLink="false">http://v-techgroup.com/?post_type=product&#038;p=2990</guid>

					<description><![CDATA[Temperature dry block Calibrator are a very common and reliable temperature source in the practice of calibration of temperature sensors, RTDs, thermocouples, transmitters, and so on. Tunix presents a portable high temperature Dry block calibrator with  <strong>working range from 800 °C from 50°C. </strong>It is best in class product for Calibration of thermometers, temperature sensors, temperature indicators.]]></description>
										<content:encoded><![CDATA[<p><strong>Applications</strong></p>
<ul>
<li>Calibration under range 50 °C to 800° C</li>
<li>Calibration of Thermocouples.</li>
<li>High temperature Sensors calibration in Pharma, process Industry.<strong>Description</strong>Model ED-800 Dry block temperature calibrator is a source calibrator in the thermal calibration process.The key parameters of that product is Accuracy, Stability on different points of temperature. Reaching time.Technical specifications are as follows.
<ol>
<li><strong>Temperature Range</strong>: 50˚C to 800 ˚C.</li>
<li><strong>Thermal stability</strong><br />
<strong>Control accuracy</strong>: ± 0.1 ˚C .</li>
<li><strong>Sound</strong>: 30 dB<br />
<strong>Power Consumption</strong>: single-phase , 1200 Watt</li>
<li><strong>Maximum Current:</strong> 5A</li>
<li><strong>Power supply</strong>: 100-240 VAC @50-60 Hz.</li>
<li><strong>Time to reach</strong> 50° C to 800˚C (30 Minutes).</li>
<li><strong>Stabilization Time/settling time</strong>: 10 minutes after set point is achieved<br />
± 0.3 ˚C @500 ˚C (calculated after stabilization time of 10 minutes).</li>
<li><strong>Thermal Nonuniformity (Radial):</strong><br />
± 0.1°C @ 300˚C (calculated after stabilization time of 10 minutes).<br />
± 0.2 ˚C @500 ˚C (calculated after stabilization time of 10 minutes).</li>
<li><strong>Enclosure</strong> :Metal(SS) Powder coated.</li>
</ol>